logo
Qingdao Yilan Cable Co., Ltd.
E-mail sales3@holdonecable.com TELEFOON 86-- 19026815676
Huis > producten > XLPE geïsoleerde kabel >
BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation
  • BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV XLPE Insulated Power Cable for Fixed Installation

Plaats van herkomst China
Merknaam QINGDAO YICABLE CABLE
Certificering CE/IEC/KEMA/VDE
Productdetails
Leidermateriaal::
Koper, IEC60228
Leidervorm::
1mm ² tot 630mm Rondschrijven ²
Isolatie::
XLPE (Cross-linked Polyethyleen), IEC60502
Buitenschede::
PVC, IEC60502
Nominale spanning Uo/U (Um)::
600/1000V, BS5467
Installatietype::
Openlucht Directe begrafenis
Markeren: 

xlpe electrical cable

,

cross linked polyethylene cable

Payment & Shipping Terms
Min. bestelaantal
200 m
Prijs
USD 1-299 Per Meter
Verpakking Details
Ijzer-houten Trommel of Gehele Houten Trommel
Levertijd
8-15 dagen
Betalingscondities
L/C, T/T, Western Union, MoneyGram,
Levering vermogen
100KM PER MAAND
Productbeschrijving

BS5467 Cu/XLPE/PVC/AWA/PVC 0.6/1kV Used for Fixed Installation

 

Cable Application

 

Cu/XLPE/PVC/AWA/PVC power cable may be used for fixed installation indoors and outdoors in cable ducts or directly in the ground.

Technical Information

Conductor Material: Copper, IEC60228
Conductor Shape: 50mm² up to 400mm² Circular
Conductor Flexibility: Stranded class 2
Outer Sheath: PVC, IEC60502
Inner Sheath: PVC, IEC60502
Insulation: XLPE (Cross-linked Polyethylene), IEC60502
Armour Type: Aluminium wires
Colour: Black
Lead Free: Yes
Rated Voltage Uo/U (Um): 600/1000V, BS5467
Installation Temperature: Minimum: 0°C Maximum: 60°C
Installation Type: Outdoor Direct burial
Operating Temperature: Minimum: -15°C Maximum: 90°C
Short-circuit Maximum Conductor Temperature: 250°C
Flame Retardant: IEC 60332-1 and BS EN 50265-2-1
Bending Radius: 50mm² up to 1000mm² = 6 x Ø

Rated voltage:0.6/1kV Low Voltage
Maximum Conductor Temperature: under normal (90℃), emergency (130℃) or short circuit no more than 5 s (250℃) conditions.
Min. Ambient Temp. 0 OC, after installation and only when cable is in a fixed position
Min. Bending Radius: 20 x cable O.D for single core without armor
15 x cable O.D for multi core without armor
15 x cable O.D for single core with armor
12 x cable O.D for multi core with armor

Standards: International: IEC 60502, IEC 60228, (IEC 60332-3 for FR-type only)
China: GB/T 12706, (GB/T 18380-3 for FR-type only)
Other standards such as BS, DIN, VDE and ICEA upon request

Installation

1. The installation temperature should not over 20℃, If the ambient temperature is lower than 0℃, the cable should be preheated.
2. The bending radius of cable should not less than 8 times.
3. After installation, the cable should with stand voltage test for 15min. 3.5kv D.C.